APPLICATION OF A NOVEL DOSE-UNCERTAINTY MODEL FOR DOSE-UNCERTAINTY ANALYSIS IN PROSTATE INTENSITY-MODULATED RADIOTHERAPY

  • Jin, Hosang
  • Palta, Jatinder R.
  • Kim, You-Hyun
  • Kim, Siyong
Citations

WEB OF SCIENCE

10
Citations

SCOPUS

11

초록

Purpose: To analyze dose uncertainty using a previously published dose-uncertainty model, and to assess potential dosimetric risks existing in prostate intensity-modulated radiotherapy (IMRT). Methods and Materials: The dose-uncertainty model provides a three-dimensional (3D) dose-uncertainty distribution in a given confidence level. For 8 retrospectively selected patients, dose-uncertainty maps were constructed using the dose-uncertainty model at the 95% CL. In addition to uncertainties inherent to the radiation treatment planning system, four scenarios of spatial errors were considered: machine only (S1), S1 + intrafraction, S1 + interfraction, and S1 + both intrafraction and interfraction errors. To evaluate the potential risks of the IMRT plans, three dose-uncertainty based plan evaluation tools were introduced: confidence-weighted dose volume histogram, confidence-weighted dose distribution, and dose-uncertainty volume histogram. Results: Dose uncertainty caused by interfraction setup error was more significant than that of intrafraction motion error. The maximum dose uncertainty (95% confidence) of the clinical target volume (CTV) was smaller than 5% of the prescribed dose in all but two cases (13.9% and 10.2%). The dose uncertainty for 95% of the CTV volume ranged from 1.3% to 2.9% of the prescribed dose. Conclusions: The dose uncertainty in prostate IMRT could be evaluated using the dose-uncertainty model. Prostate IMRT plans satisfying the same plan objectives could generate a significantly different dose uncertainty because a complex interplay of many uncertainty sources. The uncertainty-based plan evaluation contributes to generating reliable and error-resistant treatment plans. (C) 2010 Elsevier Inc.

키워드

Dose uncertaintydose-uncertainty modelprostate IMRTintrafraction motioninterfraction motionINCORPORATING ORGAN MOVEMENTSIMAGE-GUIDED RADIOTHERAPYPATIENT SETUP ERRORSRADIATION-THERAPYCONVOLUTION METHODGEOMETRIC UNCERTAINTIESINTRAFRACTION MOTIONQUANTITATIVE-EVALUATIONCOMPUTED-TOMOGRAPHYPOSITIONING ERROR
제목
APPLICATION OF A NOVEL DOSE-UNCERTAINTY MODEL FOR DOSE-UNCERTAINTY ANALYSIS IN PROSTATE INTENSITY-MODULATED RADIOTHERAPY
저자
Jin, HosangPalta, Jatinder R.Kim, You-HyunKim, Siyong
DOI
10.1016/j.ijrobp.2010.01.063
발행일
2010-11-01
유형
Article
저널명
International Journal of Radiation Oncology Biology Physics
78
3
페이지
920 ~ 928