Effect of local wall thinning on limit loads for piping branch junctions. Part 2: In-plane bending

Citations

WEB OF SCIENCE

10
Citations

SCOPUS

12

초록

This paper presents plastic limit loads of piping branch junctions with local wall thinning under in-plane bending, based on systematic three-dimensional finite element (FE) limit analyses using elastic-perfectly plastic materials. As in Part 1, an ideal branch junction without weld or reinforcement around the intersection is considered with two locations of wall thinning; one in the run pipe (opposite to the intersection), and the other in the branch pipe (next to the intersection). Based on FE results, effects of thinning geometries on plastic limit moments are quantified and simple approximations of plastic limit loads for piping branch junctions with local wall thinning under in-plane bending are proposed.

키워드

branch junction; FE limit analysis; limit bending moment; local wall thinning; FRACTURE-BEHAVIOR; INTERNAL-PRESSURE; PIPE
제목
Effect of local wall thinning on limit loads for piping branch junctions. Part 2: In-plane bending
저자
Lee, K-H; Ryu, K-M; Kim, Y-J; Park, C-Y
DOI
10.1243/03093247JSA450
발행일
2008-10
유형
Article
저널명
Journal of Strain Analysis for Engineering Design
권
43
호
7
페이지
581 ~ 594