상세 보기
초록
This paper reports the development of oiled multi-gap RPCs for use as high-rate triggers in high-energy physics experiments. The current R&D aims to improve the detector performance of RPCs in high pseudorapidity, eta, in a CMS experiment of the LHC. In this study, six-gap prototype RPCs made from 1-mm thick high pressure laminated (HPL) resistive plates were designed and built. The detector characteristics of the prototype RPCs obtained from a series of tests with cosmic muons and gamma rays are discussed. (C) 2010 Elsevier BY. All rights reserved.
키워드
Compact Muon Solenoid; Large Hadron Collider; Muon trigger detector; Aging effect; Rate capability
- 제목
- Six-gap resistive plate chambers for high-rate muon triggers
- 저자
- Lee, K. S.
- 발행일
- 2012-01-01
- 유형
- Article; Proceedings Paper
- 권
- 661
- 페이지
- S90 ~ S93