A biomechanical evaluation of proximal femoral nail antirotation with respect to helical blade position in femoral head: A cadaveric study

  • Hwang, Jin-Ho
  • Garg, Anant Kumar
  • Oh, Jong-Keon
  • Oh, Chang-Wug
  • Lee, Sung-Jae
  • 외 3명
Citations

WEB OF SCIENCE

24
Citations

SCOPUS

27

초록

Objective: Despite new developments in the management of osteoporotic fractures, complications like screw cutout are still found in the fixation of proximal femur fractures even with biomechanically proven better implants like proximal femoral nail antirotation (PFNA). The purpose of this cadaveric study was to investigate the biomechanical stability of this device in relation to two common positions (center-center and inferior-center) of the helical blade in the femoral head in unstable trochanteric fractures. Materials and Methods: Eight pairs of human cadaveric femurs were used; in one group [center-center (C-C) group], the helical blade of PFNA was fixed randomly in central position both in anteroposterior and lateral view, whereas in the other group it was fixed in inferior one-third position in anteroposterior and in central position in lateral view [inferior-center (I-C) group]. Unstable intertrochanteric fracture was created and each specimen was loaded cyclically till load to failure Results: Angular and rotational displacements were significantly higher within the C-C group compared to the I-C group in both unloaded and loaded condition. Loading to failure was higher in the I-C group compared to the C-C group. No statistical significance was found for this parameter. Correlations between tip apex distance, cyclic loading which lead to femoral head displacement, and ultimate load to failure showed a significant positive relationship. Conclusion: The I-C group was superior to the C-C group and provided better biomechanical stability for angular and rotational displacement. This study would be a stimulus for further experimental studies with larger number specimens and complex loading protocols at multicentres.

키워드

Biomechanical studycadaveric studyunstable trochanteric fracturehelical blade positionPFNADYNAMIC HIP SCREWINTERTROCHANTERIC FRACTURESPERITROCHANTERIC FRACTURESFIXATION TECHNIQUESINTERNAL-FIXATIONSIDE PLATECOMPLICATIONSPLACEMENTFAILUREMODEL
제목
A biomechanical evaluation of proximal femoral nail antirotation with respect to helical blade position in femoral head: A cadaveric study
저자
Hwang, Jin-HoGarg, Anant KumarOh, Jong-KeonOh, Chang-WugLee, Sung-JaeMyung-Rae, ChoKim, Min-KeunKim, Hyun
DOI
10.4103/0019-5413.104186
발행일
2012-11
유형
Article
저널명
Indian Journal of Orthopaedics
46
6
페이지
627 ~ 632