Wind-induced responses of super-tall buildings with various atypical building shapes

  • Kim, Y. C.
  • Tamura, Y.
  • Tanaka, H.
  • Ohtake, K.
  • Bandi, E. K.
  • 외 1명
Citations

WEB OF SCIENCE

48
Citations

SCOPUS

65

초록

A wind tunnel tests were conducted on 13 super-tall building models with atypical building shapes under an urban area flow. The primary purpose of the present study was to directly compare the wind load effects on atypical super-tall buildings. Time history analyses were conducted using a frame model by inputting local wind forces at the center of each floor. The results show that the peak normal stresses on a square model are the largest among all the models tested, the setback model shows the smallest peak normal stresses of the single modification models tested, and CC+TP+360Hel shows the smallest peak normal stresses of the multiple modification models tested. The contributions of bending moments are about 20% of the total, and most of the peak normal stresses resulted from axial force. The increase in bending moment in the across-wind direction becomes significant as the damping ratio decreases, and the sensitivity of the peak normal stresses for the helical and multiple modification models to damping ratio is smaller than those of the other models. From the analyses for the various loading conditions, it was found that the contribution of bending moment in the along-wind direction is the largest and that of torsional moment is almost negligible. (C) 2014 Elsevier Ltd. All rights reserved.

키워드

Time history analysisPeak normal stressDamping ratioLoading conditionPRESSURES
제목
Wind-induced responses of super-tall buildings with various atypical building shapes
저자
Kim, Y. C.Tamura, Y.Tanaka, H.Ohtake, K.Bandi, E. K.Yoshida, A.
DOI
10.1016/j.jweia.2014.06.004
발행일
2014-10
유형
Article; Proceedings Paper
저널명
Journal of Wind Engineering and Industrial Aerodynamics
133
페이지
191 ~ 199