Assessing lung fluid status using noninvasive bioelectrical impedance analysis in patients with acute heart failure: A pilot study

  • Lee, Sunki; 
  • Battumur, Byambakhand; 
  • Lee, Ji Eun; 
  • Park, Soo Hyung; 
  • Choi, You -Jung; 
  • ... Yong, Hwan Seok; 
  • 외 12명
Citations

WEB OF SCIENCE

8
Citations

SCOPUS

9

초록

Background: Outpatient monitoring of pulmonary congestion in heart failure (HF) patients may reduce hospitalization rates. This study tested the feasibility of non-invasive high-frequency bioelectrical impedance analysis (HF-BIA) for estimating lung fluid status. Methods: This prospective study included 70 participants: 50 with acute HF (HF group) and 20 without HF (control group). All participants underwent a supine chest CT scan to measure lung fluid content with lung density analysis software. Concurrently, direct segmental multi-frequency BIA was performed to assess the edema index (EI) of the trunk, entire body, and extremities. Results: The correlation coefficients between lung fluid content and EI measured using HF-BIA were r = 0.566 (p < 0.001) and r = 0.550 (p < 0.001) for the trunk and whole body, respectively. In the HF group, the trunk EI (0.402 +/- 0.015) and whole body EI (0.402 +/- 0.016) were significantly higher than those of the control group (trunk EI, 0.383 +/- 0.007; whole body EI, 0.383 +/- 0.007; all p < 0.001). The lung fluid content was significantly higher in the HF than that in the control group (23.7 +/- 5.3 vs. 15.5 +/- 2.8%, p < 0.001). The log value of NT proBNP was significantly correlated with trunk EI (r = 0.688, p < 0.001) and whole-body EI (r = 0.675, p < 0.001) measured by HF-BIA, and the lung fluid content analyzed by CT (r = 0.686, p < 0.001). Conclusions: BIA-based EI measurements of the trunk and whole body significantly correlated with lung fluid content and NT pro-BNP levels. Non-invasive BIA could be a promising screening tool for lung fluid status monitoring in acute HF patients.

키워드

Heart failure; Bioelectrical impedance analysis; Lung fluid content; Chest CT; Edema index; BIOIMPEDANCE ANALYSIS; PULMONARY CONGESTION; DIAGNOSIS; EDEMA
제목
Assessing lung fluid status using noninvasive bioelectrical impedance analysis in patients with acute heart failure: A pilot study
저자
Lee, Sunki; Battumur, Byambakhand; Lee, Ji Eun; Park, Soo Hyung; Choi, You -Jung; Kang, Dong Oh.; Park, Eun Jin; Lee, Dae-In; Choi, Jah Yeon; Roh, Seung Young; Na, Jin Oh.; Choi, Cheol Ung; Kim, Jin Won; Rha, Seung Woon; Park, Chang Gyu; Yong, Hwan Seok; Yang, Zepa; Kim, Eung Ju
DOI
10.1016/j.ijcard.2024.132205
발행일
2024-08-15
유형
Article
저널명
International Journal of Cardiology
권
409