Flexural Test of a Composite Beam Using Asymmetric Steel Section with Web Openings

Citations

WEB OF SCIENCE

30
Citations

SCOPUS

37

초록

As the number of high-rise buildings increases, the floor-to-floor height has been considered as a significant component due to limited city areas. To reduce the floor-to-floor height, a newly developed composite beam using asymmetric steel section with web opening was proposed and experimentally explored. Shear connectors are not used for the proposed composite beam. Instead, longitudinal shear strength is obtained through the bond strength of the interface between concrete and steel, and the bearing strength of the opened web area. In this paper, the flexural behavior of the proposed beam was assessed using the simple beam test. For comparison, a slim floor beam was tested. A bare steel beam was also tested to evaluate resistance under construction loads. The proposed system showed satisfactory horizontal shear resistance and good composite behavior.

키워드

Buildings, high-riseComposite beamsFlexural strengthSteel beamsCONCRETECOLUMNBEHAVIORJOINT
제목
Flexural Test of a Composite Beam Using Asymmetric Steel Section with Web Openings
저자
Ju, Young K.Chun, Sung-ChulKim, Sang-Dae
DOI
10.1061/(ASCE)0733-9445(2009)135:4(448)
발행일
2009-04
유형
Article
저널명
Journal of Structural Engineering
135
4
페이지
448 ~ 458