Hydrodynamic design and performance testing of Pelton-type energy recovery turbine for pressure-retarded osmosis systems

  • Park, Joo Hoon
  • Kim, Young Soo
  • Jung, In Hyuk
  • Shin, Youhwan
  • Chung, Jin Taek
Citations

WEB OF SCIENCE

3
Citations

SCOPUS

7

초록

In this paper, we present the hydrodynamic design and performance tests of a Pelton-type energy recovery turbine (ERT) for pressure-retarded osmosis (PRO) systems. We describe the process of selecting the appropriate type of ERT for operating conditions of the PRO system (i.e., 400 ton/day, 30 bar) as well as the design methods for the Pelton-type ERT. Furthermore, we analyse the performance characteristics at design and off-design points and the change in performance with respect to the diameter of the Pelton runner, based on the performance tests of the manufactured Pelton-type ERT. At the design point, the efficiency of the Pelton-type ERT was approximately 85%, and the overall efficiency with the electric generator was approximately 77.2%. The efficiency of the turbine and overall plant was highest when the diameter of the Pelton runner is of the size selected during design. We thus validate the design result through such a performance test. It is expected that this study will be of great assistance to future works involving the selection of ERTs for PRO systems, as well as the design and performance tests of ERTs.

키워드

Pressure-retarded osmosisEnergy recovery deviceHydrodynamic design of Pelton turbinePerformance testProduction of electric powerOSMOTIC POWERPLANT
제목
Hydrodynamic design and performance testing of Pelton-type energy recovery turbine for pressure-retarded osmosis systems
저자
Park, Joo HoonKim, Young SooJung, In HyukShin, YouhwanChung, Jin Taek
DOI
10.5004/dwt.2017.21660
발행일
2017-12
유형
Article
저널명
Desalination and Water Treatment
99
페이지
132 ~ 139