Experimental and Theoretical Investigation of Magnetoresistance From Linear Regime to Saturation in 14-nm FD-SOI MOS Devices

  • Shin, Minju; 
  • Shi, Ming; 
  • Mouis, Mireille; 
  • Cros, Antoine; 
  • Josse, Emmanuel; 
  • ... Kim, Gyu-Tae; 
  • 외 3명
Citations

WEB OF SCIENCE

6
Citations

SCOPUS

6

초록

The feasibility of geometric magnetoresistance (MR) measurement from linear to saturation operation regime is demonstrated in ultrathin body and BOX fully depleted silicon-on-insulator devices from 14-nm technology node. Besides, we propose a new physical compact model for MOSFET drain current under high field transport, which reproduces experimental MR mobility from linear to saturation operation region and serves as the basis for a new extraction method of carrier saturation velocity. A benchmarking with state-of-the-art saturation velocity extraction methodologies is also conducted. Our saturation velocity results indicate that, for this technology, nonstationary transport prevails as manifested by an overshoot velocity behavior, still far from the ballistic limit.

키워드

Magnetoresistance (MR); mobility; out-of-equilibrium transport; saturation regime; saturation velocity; ultrathin body and BOX (UTBB); VELOCITY OVERSHOOT; EXTRACTION; MOSFETS; PHYSICS
제목
Experimental and Theoretical Investigation of Magnetoresistance From Linear Regime to Saturation in 14-nm FD-SOI MOS Devices
저자
Shin, Minju; Shi, Ming; Mouis, Mireille; Cros, Antoine; Josse, Emmanuel; Mukhopadhyay, Sutirtha; Piot, Benjamin; Kim, Gyu-Tae; Ghibaudo, Gerard
DOI
10.1109/TED.2014.2366170
발행일
2015-01
유형
Article
저널명
IEEE Transactions on Electron Devices
권
62
호
1
페이지
3 ~ 8