상세 보기
초록
CdZnTe (CZT) crystals with thicknesses up to 20 mm and diameters up to 75 mm have become available from Redlen Technologies, Inc. for making large-volume gamma-ray detectors. The modified growth and optimized annealing conditions allowed Redlen to minimize the dark current and improve the uniformity of CZT crystals. Two detector designs, pixelated (H3D) and position-sensitive virtual Frisch-grid (VFG), have greatly benefitted from the availability of such big crystals. Encouraging results from testing of 40×40×15 mm3 pixelated detectors were recently reported by the University of Michigan. Here, we evaluated the spectroscopic properties of 8×8×32 and 10×10×32 mm3 crystals configured as position-sensitive VFG detectors. Both digitized waveforms and an analog ASIC were used to read and process the signals from the detectors and test their spectral- and spatial-resolution. The VFG design provides the flexibility to scale-up the dimensions of the detectors for the desired efficiency, while the position information allows for correcting the detectors’ response non-uniformity caused by crystal defects and devices geometry, thereby reducing the instrument cost and making them more feasible for emerging applications in gamma-ray astronomy, nonproliferation, portal screening and nuclear safeguards, where large detector arrays are often required. © 2020
키워드
- 제목
- Performance of 8?8?32 and 10?10?32 mm 3 CdZnTe position -sensitive virtual Frisch -grid detectors for high-energy gamma ray cameras
- 저자
- Bolotnikov, A. E.; MacKenzie, J.; Chen, E.; Kumar, F. J.; Taherion, S.; Carini, G.; De Geronimo, G.; Fried, J.; Kim, Kihyun; Girado, L. Ocampo; Vernon, E.; James, R. B.
- 발행일
- 2020-07-21
- 유형
- Article
- 권
- 969