Micromachined catalytic combustible hydrogen gas sensor
- Lee, Eui-Bok;
- Hwang, In-Sung;
- Cha, Jung-Ho;
- Lee, Ho-Jun;
- Lee, Won-Bae;
- ... Ju, Byeong-Kwon;
- 외 2명
Citations
WEB OF SCIENCE
136Citations
SCOPUS
152초록
An integrated catalytic combustion H-2 sensor has been fabricated by using MEMS technology. Both the sensing elements and the reference elements could be integrated into the suspended micro heaters connected in a suitable circuit such as a Wheatstone configuration with low power consumption. Two sensitive elements and two reference sensors were integrated together onto a single chip. The size of chip was 5.76 mm(2) and the catalytic combustion sensor showed high response to H-2 at operating voltage of 1 V. The response and recovery times to 1000 ppm H-2 were 0.36 s and 1.29 s, respectively. (C) 2010 Elsevier B.V. All rights reserved.
키워드
Catalytic combustion; MEMS; Hydrogen gas sensor; PELLISTOR ARRAY; FILMS