High-rate performance of a time projection chamber for an H-dibaryon search experiment at J-PARC

  • Kim, S. H.
  • Ichikawa, Y.
  • Sako, H.
  • Ahn, J. K.
  • Akaishi, T.
  • 외 15명
Citations

WEB OF SCIENCE

6
Citations

SCOPUS

10

초록

We have developed a gas electron multiplier (GEM)-based time projection chamber (TPC) for the H-dibaryon search experiment at J-PARC. High-rate K- beam particles enter a TPC gas volume of approximately 0.2 m(3), in a direction perpendicular to the electric field. A long-rectangular hollow section is located inside the TPC volume to accommodate a diamond target. We commissioned the TPC using 230-MeV protons with beam rates of up to 1 MHz. The TPC data acquisition system collected 5768 pad signals in full readout mode, with almost 100% efficiency, at a preset trigger rate of 230 Hz. We operated the TPC in an Ar/CH4 gas mixture (90/10) without a magnetic field. The spatial resolutions on the pad plane are measured to be 400-700 mu m, which correspond to 230-300 mu m in a magnetic field of 1 T. We confirmed high tracking capability at beam rates of up to 1 MHz.

키워드

Time projection chamberGas electron multiplierJ-PARCGEMSYSTEM
제목
High-rate performance of a time projection chamber for an H-dibaryon search experiment at J-PARC
저자
Kim, S. H.Ichikawa, Y.Sako, H.Ahn, J. K.Akaishi, T.Ashikaga, S.Choi, S. W.Ekawa, H.Hasegawa, S.Hayakawa, S.Jung, W. S.Kang, B. M.Lee, J. Y.Nanamura, T.Sato, S.Shirotori, K.Suzuki, K.Tanida, K.Yang, S. B.Yoshida, J.
DOI
10.1016/j.nima.2019.06.050
발행일
2019-10-01
유형
Article
저널명
Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
940
페이지
359 ~ 370