Length-stable fixation reduces femoral neck shortening in unstable femoral neck fractures: A retrospective comparative study of length-stable dynamic hip screw versus femoral neck system fixation

  • Kang, Seonghyun; 
  • Choi, Wonseok; 
  • Choi, Jeong Seok; 
  • Lim, Eic Ju; 
  • Ahn, Sungjin; 
  • 외 4명
Citations

WEB OF SCIENCE

0
Citations

SCOPUS

0

초록

BackgroundFemoral neck shortening following internal fixation of unstable femoral neck fractures can compromise functional recovery, particularly in young, active patients. This study aimed to evaluate the efficacy of a length-stable dynamic hip screw (LSD) construct in minimizing postoperative shortening compared to the femoral neck system (FNS).MethodsA retrospective review was conducted on 65 patients with high-grade unstable femoral neck fractures treated between February 2016 and February 2023 at a single institution. Patients underwent either FNS (n = 31) or LSD (n = 34) fixation. Femoral neck shortening was quantified using vector-based analysis derived from contralateral femoral comparison at final follow-up. Functional outcomes were assessed using the Hip Disability and Osteoarthritis Outcome Score (HOOS).ResultsThe LSD group demonstrated significantly less femoral neck shortening compared to the FNS group (5.0 +/- 4.6 mm vs 10.4 +/- 6.7 mm, p = 0.001). Final HOOS scores were significantly higher in the LSD group in the symptom (88.1 vs 75.8, p = 0.049) and stiffness subdomains. Union was achieved in 31 of 34 patients (91.2%) in the LSD group and 26 of 31 (83.9%) in the FNS group (p = 0.605). Other complications were more frequent in the FNS group but did not reach statistical significance.ConclusionLength-stable fixation using the LSD construct significantly reduced postoperative femoral neck shortening in high-grade unstable fractures, without compromising union rates or functional recovery. Our results support the role of length-stable constructs as a reliable option for maintaining anatomic integrity in unstable femoral neck fractures.

키워드

femoral neck fracture; femoral neck shortening; length-stable construct; dynamic hip screw; femoral neck system; CANNULATED SCREW
제목
Length-stable fixation reduces femoral neck shortening in unstable femoral neck fractures: A retrospective comparative study of length-stable dynamic hip screw versus femoral neck system fixation
저자
Kang, Seonghyun; Choi, Wonseok; Choi, Jeong Seok; Lim, Eic Ju; Ahn, Sungjin; Oh, Jong-Keon; Kent, William T.; Son, Whee Sung; Cho, Jae-Woo
DOI
10.1177/10225536261415697
발행일
2026-01
유형
Article
저널명
Journal of Orthopaedic Surgery
권
34
호
1