상세 보기
초록
Eight ultra-high-strength concrete (UHSC) square columns were constructed and tested to investigate the effects of yield strength of transverse (f(yh) approximate to 550 and 800 MPa [79.8 and 116.0 ksi]) and longitudinal reinforcement (f(yh) approximate to 480 and 640 MPa [69.6 and 92.8 ksi]) on axial load response. The UHSC had compressive strengths varying from 185 to 200 MPa (26.8 to 29.0 ksi). The effects of using high-strength transverse reinforcement with two different configurations and amounts were evaluated. For a constant amount of confinement reinforcement, high-strength transverse reinforcement improves the performance of well-confined UHSC columns in terms of strength, post-peak deformability, and toughness, provided that the hoops are detailed with proper end anchorage (135-degree seismic hooks). The use of high-strength transverse reinforcement was also effective in reducing steel congestion for UHSC columns. The effects of using high-strength longitudinal reinforcement in UHSC columns were also studied. It was determined that the combination of high-strength longitudinal reinforcement and UHSC results in yielding of this reinforcement. However, for typical longitudinal reinforcement ratios, the benefit of using high-strength longitudinal steel is limited due to the relatively small contribution of this reinforcement to the strength of UHSC columns and the early cover spalling of UHSC.
키워드
- 제목
- Axial Load Response of Ultra-High-Strength Concrete Columns and High-Strength Reinforcement
- 저자
- Shin, Hyun-Oh; Yoon, Young-Soo; Cook, William D.; Mitchell, Denis
- 발행일
- 2016-03
- 유형
- Article
- 권
- 113
- 호
- 2
- 페이지
- 325 ~ 336