Seismic Behavior of Monolithic Exterior Beam-Column Connections with Unbonded Post-Tensioning

  • Kim, Sanghee
  • Kang, Thomas H. -K.
  • Jung, Donghyuk
  • Kwon, Byung Un
  • Lee, Dong Joo
Citations

WEB OF SCIENCE

4
Citations

SCOPUS

3

초록

This paper presents experimental results on seismic behaviors of post-tensioned (PT) monolithic exterior beam-column connections. Lateral cyclic loading tests were carried out for six fullscale exterior beam-column joint subassemblies fabricated with normal- and high-strength materials. Despite substantial joint cover spalling, the normal-strength specimens exhibited satisfactory lateral strengths and hysteretic behaviors up to +/- 5% drift ratios by virtue of the confinement effect of post-tensioning. The high-strength PT specimens also showed stable hysteretic behaviors with significantly reduced joint damages. It was found that the post-tensioning can increase the joint shear strength by more than 60% in both types of specimens. Furthermore, the post-tensioning was effective in retaining the lateral stiffness of the beam-column joints under the repeated loads, especially in high-strength specimens, enabling them to maintain at least 90% of their first-cycle stiffnesses throughout the testing.

키워드

cyclic testexterior beam-column connectionhigh-strength concrete (HSC)joint shear demandjoint shear strengthmonolithic connectiontendonsunbonded post-tensioningSTRENGTHDESIGN
제목
Seismic Behavior of Monolithic Exterior Beam-Column Connections with Unbonded Post-Tensioning
저자
Kim, SangheeKang, Thomas H. -K.Jung, DonghyukKwon, Byung UnLee, Dong Joo
DOI
10.14359/51739085,
발행일
2023-11
유형
Article
저널명
ACI Structural Journal
120
6
페이지
49 ~ 62