Interfacial shear resistance of angle shear connectors welded to concrete filled U-shaped CFS beam

Citations

WEB OF SCIENCE

3
Citations

SCOPUS

2

초록

For multi-story structural systems, Korean steel industry has fostered development of a steel-concrete composite beam. Configuration of the composite beam is characterized by steel angle shear connectors welded to a U-shaped cold formed-steel beam. Effects of shear connector orientation and spacing were studied to evaluate current application of the angle shear connector design equation in AC495. For the study, interfacial shear resistance behavior was investigated by conducting 24 push-out tests and attuned using unreinforced push-out specimens. Interfacial shear to horizontal slip response was reported along with corresponding failure patterns. Pure shear connector strength was also evaluated by excluding concrete shear contribution, which was estimated in relation to steel beam-slab interface separation or interfacial crack width.

키워드

aggregate interlocking resistance; angle; channel; cold formed-steel; composite beam; concrete; interfacial shear strength; push-out test; shear connector; U-shaped section; BEHAVIOR; SLAB
제목
Interfacial shear resistance of angle shear connectors welded to concrete filled U-shaped CFS beam
저자
Oh, Hyoung Seok; Shin, Hyeongyeop; Ju, Youngkyu; Kang, Thomas H. -K.
DOI
10.12989/scs.2022.43.3.311
발행일
2022-05-10
유형
Article
저널명
Steel and Composite Structures, An International Journal
권
43
호
3
페이지
311 ~ 325