Improved diagnostic performance of CT-derived FFR using 70-keV monoenergetic spectral CT in coronary artery disease

  • Bakhjanar, Gylymkhan; 
  • Cha, Jung-Joon; 
  • Oh, Yu-Whan; 
  • Yu, Cheol Woong; 
  • Park, Seong-Mi; 
  • ... Hwang, Sung Ho; 
  • 외 1명
Citations

WEB OF SCIENCE

0
Citations

SCOPUS

0

초록

To compare the diagnostic performance of coronary CT-derived fractional flow reserve (CT-FFR) calculated from conventional polychromatic CT images with 70-keV monoenergetic reconstructions derived from spectral CT data. This retrospective study enrolled patients who underwent spectral coronary CT angiography followed by invasive FFR measurements. The CT-FFR values were computed from conventional polychromatic and 70-keV monoenergetic images. Image quality was assessed using the contrast-to-noise ratio (CNR). Comparison of the CT-FFR with invasive FFR provided mean absolute error (MAE), Pearson's correlation, Bland-Altman analysis, and receiver operating characteristic (ROC) curve analysis. Hemodynamically significant stenosis was defined as an invasive FFR < 0.80. Thirty-two patients (21 men, 11 women; mean age, 68.5 +/- 8.4 years) with 47 coronary artery lesions were included in this study. The 70-keV images demonstrated significantly higher CNR than conventional images (36.4 +/- 15.2 vs. 25.3 +/- 7.4; p < 0.01). CT-FFR derived from 70-keV images yielded lower MAE (0.07 +/- 0.05 vs. 0.12 +/- 0.08; p < 0.01) and showed stronger correlation with invasive FFR (R = 0.769 vs. R = 0.439). Bland-Altman analysis revealed narrower limits of agreement for the 70-keV CT-FFR. In 17 lesions with hemodynamically significant stenosis, the area under the ROC curve of 70-keV CT-FFR was significantly higher than that of conventional CT-FFR (0.929 vs. 0.807; p = 0.01). CT-FFR derived from 70-keV monoenergetic spectral CT images demonstrated promising agreement with invasive FFR and may offer exploratory insight into improving functional assessment of coronary stenosis.

키워드

Coronary artery disease; Tomography, X-Ray computed; Fractional flow reserve, myocardial; Spectral imaging; Image processing, Computer-Assisted; FRACTIONAL FLOW RESERVE; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; ENERGY; IMPACT
제목
Improved diagnostic performance of CT-derived FFR using 70-keV monoenergetic spectral CT in coronary artery disease
저자
Bakhjanar, Gylymkhan; Cha, Jung-Joon; Oh, Yu-Whan; Yu, Cheol Woong; Park, Seong-Mi; Cho, Dong Hyuk; Hwang, Sung Ho
DOI
10.1007/s10554-026-03613-z
발행일
2026-04
유형
Article
저널명
International Journal of Cardiovascular Imaging
권
42
호
4
페이지
677 ~ 685