In-situ virtual heat flow meter model for monitoring heat flux of existing building envelope
- Jung, Dong Eun;
- Shin, Dae Hwan;
- Seo, Jihyun;
- Lee, Kwang Ho;
- Kim, Jonghun
WEB OF SCIENCE
12SCOPUS
11초록
In the building sector, remodeling of existing buildings that have low energy efficiency is a required strategy to achieve carbon neutrality. To establish a cost-effective remodeling strategy for existing buildings, accurate measurement of the thermal insulation performance of existing building envelopes is necessary. In general, to evaluate the insulation performance of a building envelope, the U-value is calculated based on the heat flux measured using a heat flow meter, which is an expensive physical sensor. This study developed an in -situ virtual heat flow meter (vHFM) model that can replace existing heat flow meter sensors. The in -situ vHFM model satisfied ASHRAE Guideline 14 with an R2 of 0.989, coefficient of variation root mean square error of 15.24%, and normalized mean bias error of -0.06% compared to the data measured using a traditional sensor. In addition, the validation through two case studies demonstrated that the field applicability of the in -situ vHFM model was very high.
키워드
- 제목
- In-situ virtual heat flow meter model for monitoring heat flux of existing building envelope
- 저자
- Jung, Dong Eun; Shin, Dae Hwan; Seo, Jihyun; Lee, Kwang Ho; Kim, Jonghun
- 발행일
- 2024-04-01
- 유형
- Article
- 권