In-situ virtual heat flow meter model for monitoring heat flux of existing building envelope

Citations

WEB OF SCIENCE

12
Citations

SCOPUS

11

초록

In the building sector, remodeling of existing buildings that have low energy efficiency is a required strategy to achieve carbon neutrality. To establish a cost-effective remodeling strategy for existing buildings, accurate measurement of the thermal insulation performance of existing building envelopes is necessary. In general, to evaluate the insulation performance of a building envelope, the U-value is calculated based on the heat flux measured using a heat flow meter, which is an expensive physical sensor. This study developed an in -situ virtual heat flow meter (vHFM) model that can replace existing heat flow meter sensors. The in -situ vHFM model satisfied ASHRAE Guideline 14 with an R2 of 0.989, coefficient of variation root mean square error of 15.24%, and normalized mean bias error of -0.06% compared to the data measured using a traditional sensor. In addition, the validation through two case studies demonstrated that the field applicability of the in -situ vHFM model was very high.

키워드

Building envelope; Heat flow meter; Virtual sensor; In -situ virtual heat flow meter model; SENSOR
제목
In-situ virtual heat flow meter model for monitoring heat flux of existing building envelope
저자
Jung, Dong Eun; Shin, Dae Hwan; Seo, Jihyun; Lee, Kwang Ho; Kim, Jonghun
DOI
10.1016/j.buildenv.2024.111320
발행일
2024-04-01
유형
Article
저널명
Building and Environment
권
253