Filtration Performance Characteristics of Sticky Aerosol Using Calcium Hydroxide

  • Lee, Jae-Rang
  • Hasolli, Naim
  • Jeon, Seong-Min
  • Lee, Kang-San
  • Gang, Jun-Hyeok
  • 외 3명
Citations

WEB OF SCIENCE

2
Citations

SCOPUS

4

초록

This study examined the performance of removing aerosol upon a flow rate variable by agglomerating sticky aerosol with calcium hydroxide and removing cohesive aerosol through an experimental apparatus, simulating an actual painting booth. As a result of examining the performance of the filter by fixing the paint spray quantity, the calcium hydroxide input and the filtration area under variable flow rates of 5, 10, and 15 Nm(3)/min, we confirmed that the filter performance has long average aerosol removing intervals at the 5 Nm(3)/min flow rate. At the 5 Nm(3)/min flow rate, there is a low residual pressure drop trend and high fractional collection efficiency, and a high level of total collection efficiency is maintained at 99.42%. When the flow rate is less than 5 Nm(3)/min, the aerosol settling and experimentation was impossible. With this research, the optimal conditions for the use of sticky aerosol have been examined.

키워드

sticky aerosolcalcium hydroxideflow ratefiltertotal collection efficiencyFILTERS