상세 보기
초록
Two types of connection between the abutment and CFT pile were proposed for the sub-structure of the integral abutment bridge. One was a bolt connection (Type-A) and the other was a hook connection (Type-B). To analyze the performance of connection Type-A and Type-B, a quasi-static experiment was carried out. According to experimental results, the destruction occurred at the connection point and so both type A and type B need to have a reinforced design as the link between the abutment and CFT pile. However, when the load resistance performance and energy dissipation capacity was analyzed, the performance of connection Type-B was superior to the performance of connection Type-A.
키워드
integral abutment bridge; CFT pile; connection performance; 일체식 교대 교량; 콘크리트 충전 강관; 연결부 성능
- 제목
- 일체식 교량의 교대와 CFT Pile 연결부 성능에 관한 실험적 연구
- 제목 (타언어)
- Experimental Study on Performance of Connection Between the Abutment and CFT Pile in Integral Abutment Bridge
- 저자
- 김대혁; 한상윤; 이호찬; 신성진; 강영종
- 발행일
- 2016
- 저널명
- 한국복합신소재구조학회 논문집
- 권
- 7
- 호
- 3
- 페이지
- 47 ~ 54