Evaluation of fully automated commercial software for Agatston calcium scoring on non-ECG-gated low-dose chest CT with different slice thickness

  • Kang, Hyun Woo
  • Ahn, Woo Jin
  • Jeong, Ju Hyun
  • Suh, Young Joo
  • Yang, Dong Hyun
  • 외 6명
Citations

WEB OF SCIENCE

19
Citations

SCOPUS

22

초록

Objectives To evaluate commercial deep learning-based software for fully automated coronary artery calcium (CAC) scoring on non-electrocardiogram (ECG)-gated low-dose CT (LDCT) with different slice thicknesses compared with manual ECG-gated calcium-scoring CT (CSCT). Methods This retrospective study included 567 patients who underwent both LDCT and CSCT. All LDCT images were reconstructed with a 2.5-mm slice thickness (LDCT2.5-mm), and 453 LDCT scans were reconstructed with a 1.0-mm slice thickness (LDCT1.0-mm). Automated CAC scoring was performed on CSCT (CSCTauto), LDCT1.0-mm, and LDCT2.5-mm images. The reliability of CSCTauto, LDCT1.0-mm, and LDCT2.5-mm was compared with manual CSCT scoring (CSCTmanual) using intraclass correlation coefficients (ICCs) and Bland-Altman analysis. Agreement, in CAC severity category, was analyzed using weighted kappa statistics. Diagnostic performance at various Agatston score cutoffs was also calculated. Results CSCTauto, LDCT1.0-mm, and LDCT2.5-mm demonstrated excellent agreement with CSCTmanual (ICC [95% confidence interval, CI]: 1.000 [1.000, 1.000], 0.937 [0.917, 0.952], and 0.955 [0.946, 0.963], respectively). The mean difference with 95% limits of agreement was lower with LDCT1.0-mm than with LDCT2.5-mm (19.94 [95% CI, -244.0, 283.9] vs. 45.26 [-248.2, 338.7]). Regarding CAC severity, LDCT1.0-mm achieved almost perfect agreement, and LDCT2.5-mm achieved substantial agreement (kappa [95% CI]: 0.809 [0.776, 0.838], 0.776 [0.740, 0.809], respectively). Diagnostic performance for detecting Agatston score >= 400 was also higher with LDCT1.0-mm than with LDCT2.5-mm (F1 score, 0.929 vs. 0.855). Conclusions Fully automated CAC-scoring software with both CSCT and LDCT yielded excellent reliability and agreement with CSCTmanual. LDCT1.0-mm yielded more accurate Agatston scoring than LDCT2.5-mm using fully automated commercial software.

키워드

Artificial intelligenceSoftwareCoronary arteriesCalciumTomographyX-ray computedCORONARY-ARTERY CALCIUMELECTRON-BEAM CTCOMPUTED-TOMOGRAPHYCALCIFICATIONASSOCIATIONVALIDATIONAGREEMENT
제목
Evaluation of fully automated commercial software for Agatston calcium scoring on non-ECG-gated low-dose chest CT with different slice thickness
저자
Kang, Hyun WooAhn, Woo JinJeong, Ju HyunSuh, Young JooYang, Dong HyunChoi, HangseokHwang, Sung HoYong, Hwan SeokOh, Yu-WhanKang, Eun-YoungKim, Cherry
DOI
10.1007/s00330-022-09143-1
발행일
2023-03-01
유형
Article
저널명
European Radiology
33
3
페이지
1973 ~ 1981