Implant Ball Attachment Fabricated with CAD/CAM to Overcome an Unfavorable Clinical Situation: A Case Report

Citations

WEB OF SCIENCE

2
Citations

SCOPUS

1

초록

The most common complication of implant ball attachments is loss of retention via structural wear. Hence, parallel placement of implants was identified as a prerequisite for long-term success. In this case, although severe angulation was formed between implants due to severe alveolar bone resorption, parallel ball attachments on the implants could be fabricated using computer-aided design/computer-assisted manufacture. This procedure can be a solution when implants are placed with angulation and offers additional advantages such as long-term stability.

키워드

OVERDENTURES
제목
Implant Ball Attachment Fabricated with CAD/CAM to Overcome an Unfavorable Clinical Situation: A Case Report
저자
Shim, Ji SukLim, Jae HyungShin, Jung HyunRyu, Jae JunLee, Jeong YolShin, Sang Wan
DOI
10.11607/ijp.4914
발행일
2016-11
유형
Article
저널명
International Journal of Prosthodontics
29
6
페이지
611 ~ 613