Investigation of a concrete railway sleeper failed by ice expansion

  • Zi, Goangseup
  • Moon, Do Young
  • Lee, Seung-Jung
  • Jang, Seung Yup
  • Yang, Sin Chu
  • 외 1명
Citations

WEB OF SCIENCE

27
Citations

SCOPUS

28

초록

We investigated a conical crack formed near a fastening bolt of a concrete railway sleeper in a slab track system. The crack initiated from the bottom of the sleeper and penetrated the sleeper completely forming a conical shape. To study the reason for this and to examine the failure mechanism, we used a three dimensional finite element method and a series of experimental programs. The result of the numerical simulation was verified with the experimental data. From this study, we concluded that the conical crack was caused by the volume expansion of the freezing water leaking into the plastic insert of the fastener hole. The effect of location of the frozen insert holes, initial fastening force and compressive strength of concrete on the freezing force was also studied in this study. (C) 2012 Elsevier Ltd. All rights reserved.

키워드

Concrete railway sleeperFractureFinite element modelIce expansionSlab trackCOHESIVE CRACKSFRACTUREPARAMETERS
제목
Investigation of a concrete railway sleeper failed by ice expansion
저자
Zi, GoangseupMoon, Do YoungLee, Seung-JungJang, Seung YupYang, Sin ChuKim, Soo-Sam
DOI
10.1016/j.engfailanal.2012.07.023
발행일
2012-12
유형
Article; Proceedings Paper
저널명
Engineering Failure Analysis
26
페이지
151 ~ 163