Failure Analysis of the Defect-Induced Blade Damage of a Compressor in the Gas Turbine of a Cogeneration Plant

  • Yoon, Wan No
  • Kang, Myung Soo
  • Jung, Nam Kun
  • Kim, Jun Sung
  • Choi, Byoung-Ho
Citations

WEB OF SCIENCE

16
Citations

SCOPUS

17

초록

Gas turbine engines are being widely used for power generation recently because of their high efficiency and versatility. However, it is occasionally reported that a gas turbine under normal operation fails even though careful inspections were scheduled. In this paper, the recent failure of the gas turbines of a cogeneration plant is analyzed by focusing mainly on the crack initiation mechanism of blade fracture. Damage of several blades of the compressor was observed after a gas turbine was disassembled, and the root causes of the damage were investigated in detail by scanning electron microscopy as well as optical microscopy. The defects observed at the crack initiation site have been characterized by comparison with previous studies. The fracture of the blade was supposed to be initiated by a crack due to concentrated stresses around a preexisting defect which was possibly formed before the turbine was operated, e.g., a forging defect during the three-step forging process for blades manufacture.

키워드

Failure analysisBlade damageGas turbineCogeneration plantForging defectFATIGUESYSTEMSPOWER
제목
Failure Analysis of the Defect-Induced Blade Damage of a Compressor in the Gas Turbine of a Cogeneration Plant
저자
Yoon, Wan NoKang, Myung SooJung, Nam KunKim, Jun SungChoi, Byoung-Ho
DOI
10.1007/s12541-012-0093-4
발행일
2012-05
유형
Article
저널명
International Journal of Precision Engineering and Manufacturing
13
5
페이지
717 ~ 722