Development of high efficiency cycles for domestic refrigerator-freezer application
- Yang, Mina;
- Jung, Chung Woo;
- Kang, Yong Tae
WEB OF SCIENCE
24SCOPUS
26초록
High efficiency 2-stage vapor compression cycles are developed for domestic refrigerator-freezer application. From the parametric analysis of the newly developed cycles, it is recommended that evaporators be connected in series while compressors be connected in parallel to obtain the highest COP (coefficient of performance) in domestic refrigerator-freezer systems. It is found that the most important parameter for performance improvement is the freezing load ratio (R-(Q) over dotF = (Q) over dot(F)/(Q) over dot(total)). It is also found that the degree of subcooling by the heat exchanger (Delta T-sub = T-2 - T-3) gives the most significant effect on (m) over dot(total). However, there are some difficulties in operating the newly developed cycle such as difficult individual operation of the evaporators. Therefore, this study proposes an advanced novel cycle with the evaporators connected in parallel and without the separator, which is named "two-circuit cycle with evaporating subcooler". It is finally concluded that the refrigerants pair of (R/F) = (R152a/R600a) be the best candidate with the highest COP of 3.758 for the two-circuit cycle with evaporating subcooler. (C) 2015 Elsevier Ltd. All rights reserved.
키워드
- 제목
- Development of high efficiency cycles for domestic refrigerator-freezer application
- 저자
- Yang, Mina; Jung, Chung Woo; Kang, Yong Tae
- 발행일
- 2015-12-15
- 유형
- Article
- 저널명
- Energy
- 권
- 93
- 페이지
- 2258 ~ 2266
- 언어
- ENG
- 출판사
- PERGAMON-ELSEVIER SCIENCE LTD
- 발행국가
- 영국
- 분량
- 9 페이지
- ISSN
- E 1873-6785
P 0360-5442