Test of a four-gap resistive plate chamber with cosmic muons and high-rate gamma rays

  • Park, S. K.
  • Shin, S. S.
  • Hong, B.
  • Jhang, G.
  • Jeong, M. S.
  • 외 13명
Citations

WEB OF SCIENCE

1
Citations

SCOPUS

1

초록

We report a new development of a phenolic four-gap resistive plate chamber (RPC) for use as a high-rate particle trigger in high-energy physics experiments. In the current study, a prototype RPC equipped with four 1-mm-thick gaps made from high-pressure-laminated (HPL) resistive plates has been designed and built. The current detector R&D aims to reduce the probability of radiation-induced degradation of the core detector components of the RPCs, the gas gaps, as well as to improve the detection rate capability. The detector characteristics of the four-gap RPC were obtained though a series of tests with cosmic muons and gamma rays and were compared with those of the typical 2-mm thick double-gap RPCs currently used in the CMS experiment at the LHC and in the PHENIX experiment at the RHIC. (C) 2012 Elsevier B.V. All rights reserved.

키워드

Multigap RPCsMuon trigger detectorsHPLRate capabilityAging effectRPCSCMSSIMULATIONCMS/LHC
제목
Test of a four-gap resistive plate chamber with cosmic muons and high-rate gamma rays
저자
Park, S. K.Shin, S. S.Hong, B.Jhang, G.Jeong, M. S.Jo, M.Cho, S. W.Joo, E.Kim, C.Kim, H. C.Lee, K. S.Lee, K. S.Lee, S.Lee, S. K.Lim, J. K.Moon, D. H.Shim, H. H.Sim, K. S.
DOI
10.1016/j.nima.2012.03.039
발행일
2012-07-11
유형
Article
저널명
Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
680
페이지
134 ~ 138