IEC 60079-10-1 edition 2.0에 의한 방폭 설계 한계점 보완 방법에 관한 연구

A Study on Complementary Method for Hazardous Area Extent by IEC 60079-10-1 Edition 2.0
  • 최재영
  • 변상훈

초록

IEC 60079-10-1 edition 2.0, the global standard for hazardous area classification, was newly revised in 2015. There are many differences compared to the previous edition 1.0 version, first released in 2008, so it has caused confusion in the industry. In case of edition 1.0, the hazardous area extent can be derived through the mathematical formula, but in case of edition 2.0, there was the problem that the exact hazardous area extent was not known because of the mathematical formula of the plot for applying the hazardous area extent was not presented. In this study, we converted the plot introduced in edition 2.0 to CAD format and derived the plot as the mathematical equations. Through this, we suggest the hazardous area extent formula of three states (heavy gas, diffusive, jet). As the IEC committee did not provide the mathematical formula of the hazardous area extent according to the release characteristic, it is impossible to apply the exact hazardous area extent. In this study, a mathematical approach was derived for the plot introduced in edition 2.0, which can reduce the confusion of the applying hazardous area extent.

키워드

Hazardous Area ClassificationIEC 60079-10-1Characteristic of ReleaseProcess SafetyExplosive Atmosphere
제목
IEC 60079-10-1 edition 2.0에 의한 방폭 설계 한계점 보완 방법에 관한 연구
제목 (타언어)
A Study on Complementary Method for Hazardous Area Extent by IEC 60079-10-1 Edition 2.0
저자
최재영변상훈
발행일
2020
저널명
Journal of Korea Safety Management & Science
22
2
페이지
73 ~ 82