네트워크 부하 조건의 변화가 채널 상태 정보에 미치는 영향을 고려한 옥내 전력선 통신 채널의 채널 용량 분석

Channel Capacity Analysis for Indoor PLC Networks with Considering the Effect of Loading conditions of Networks on Channel State Information
  • 신재영
  • 정지채

초록

We analyze the channel capacity with considering the effect of the loading conditions of indoor PLC networks on channel state information. We consider various numbers of load for two kinds of the networks with regular length branches and a deployed network of indoor PLC. For calculating the channel capacity degradation, two noise scenarios and impedances are considered. From the simulation results, we suggest the robust regression lines for modeling the channel capacity degradation. In the cases of 0 Ω and Z0loads, natural log and linear function curve show the best goodness of fit, respectively. For the deployed indoor PLC network with 0 Ω loads, compared with the networks with regular length branches, the goodness of fit decreases by the amount of 0.12 and 0.15 for low noise and high noise scenarios, respectively. Using the regression lines, we can estimate the channel capacity degradation without measurement.

키워드

Channel capacityChannel state informationPLCPower-line communications
제목
네트워크 부하 조건의 변화가 채널 상태 정보에 미치는 영향을 고려한 옥내 전력선 통신 채널의 채널 용량 분석
제목 (타언어)
Channel Capacity Analysis for Indoor PLC Networks with Considering the Effect of Loading conditions of Networks on Channel State Information
저자
신재영정지채
발행일
2011
저널명
전기학회논문지
60
2
페이지
252 ~ 256