Characterization and modeling of slow crack growth behaviors of defective high-density polyethylene pipes using stiff-constant K specimen

  • Wee, Jung-Wook
  • Kim, Ilhyun
  • Choi, Min-Seok
  • Park, Sang-Kyu
  • Choi, Byoung-Ho
Citations

WEB OF SCIENCE

18
Citations

SCOPUS

19

초록

In this study, slow crack growth (SCG) resistances of defective and normal high density polyethylene (HDPE) pipes were measured using the stiff-constant K (SCK) specimen, where the stress intensity factor (SIF) was maintained at a constant value within a certain crack length range. A significantly reduced SCG resistance was observed in the defective pipe; a detailed procedure for evaluating SCG kinetics using the SCK specimen has been provided herein. The results of a fracture surface analysis indicate that the white window patterns, resulting from poor carbon black dispersion, are the main reason for poor SCG performance. In addition, a crack layer (CL) model was derived for the SCK specimen geometry and was compared with experimental results. It was observed that the crack and process zone growth resistance parameters were significantly lower in the case of the defected pipe than those in the case of the normal pipe.

키워드

PolyethyleneDefective pipeSlow crack growthStiff-constant K specimenFracture analysisCrack layer theoryCARBON-BLACK DISTRIBUTIONLAYER THEORYSTEPWISE FATIGUELIFETIMEFAILUREFRACTUREDEGRADATIONPROPAGATIONPERFORMANCEPREDICTION
제목
Characterization and modeling of slow crack growth behaviors of defective high-density polyethylene pipes using stiff-constant K specimen
저자
Wee, Jung-WookKim, IlhyunChoi, Min-SeokPark, Sang-KyuChoi, Byoung-Ho
DOI
10.1016/j.polymertesting.2020.106499
발행일
2020-06
유형
Article
저널명
Polymer Testing
86