Non-contact measurement of current distribution in parallel conductors by using Hall sensors
- Park, Myungjin;
- Byun, Sangbeom;
- Kim, Wooseok;
- Lee, Jikwang;
- Choi, Kyeongdal;
- ... Lee, Haigun
Citations
WEB OF SCIENCE
11초록
A parallel HTS conductor to flow large current is essential for applications of HTS power device. Non-uniform current distribution in the parallel conductor is caused mainly due to the difference of inductance. There are a contact method which measures current directly and a non-contact method which measure indirectly. But current distribution of each conductor in parallel conductors can not be measured with conventional method. In this paper, we researched a measurement method to identify current distribution of the parallel conductor indirectly with Hall sensors and compared with the analysis results by 2-D FEM.
키워드
current distribution; Hall sensor; HTS; SUPERCONDUCTING CABLES; MODEL COIL; FIELD
- 제목
- Non-contact measurement of current distribution in parallel conductors by using Hall sensors
- 저자
- Park, Myungjin; Byun, Sangbeom; Kim, Wooseok; Lee, Jikwang; Choi, Kyeongdal; Lee, Haigun
- 발행일
- 2008-06
- 유형
- Article; Proceedings Paper
- 권
- 18
- 호
- 2
- 페이지
- 1135 ~ 1138