상세 보기
초록
In this study, a method to determine the design capacities of nonpoint source (NPS) pollutant treatment facilities in urban areas was suggested. A facility capacity to treat 80 percent of total SS discharge was estimated by 2-year rainfall - runoff - build-up and wash-off simulation at Goonja drainage district in Seoul. For wash-off simulation, four wash-off models (EMC, RC, EXP, and Joo model) were used. As the results, 80 percent of total SS discharge could be treated with only 7.7~31.4% facility capacity of peak flow. The suggested method and results will provide a guideline to determine design capacities of NPS pollutant treatment facility in urban areas.
키워드
Long-term simulation; Non-point source pollutant; SWMM; Treatment
- 제목
- 장기모의를 통한 도시유역 비점오염원 처리장치 용량 산정
- 제목 (타언어)
- Determination of Design Capacity for NPS Pollutant Treatment Facilities by Long-term Simulation in Urban Areas
- 저자
- 주진걸; 유도근; 김중훈
- 발행일
- 2011
- 저널명
- 한국물환경학회지
- 권
- 27
- 호
- 6
- 페이지
- 841 ~ 847