Performance optimization of dual-loop cycles using R-600a and hydrocarbon mixtures designed for a domestic refrigerator-freezer

  • Yoon, Won Jae
  • Seo, Kookjeong
  • Chung, Hyun Joon
  • Kim, Yongchan
Citations

WEB OF SCIENCE

31

초록

A dual-loop cycle for a domestic refrigerator-freezer (RF) has a large energy saving potential because it has a lower compression ratio due to a higher evaporating temperature in the fresh food compartment (R)-operation compared to a conventional refrigeration cycle, as well as individual optimization flexibility for each loop. In this study, optimizations of dual-loop cycles using R-600a and hydrocarbon (HC) mixtures were individually carried out. Each optimization process included both a theoretical analysis and an experimental investigation. The theoretical analysis was conducted to optimize the specifications of cycle components and the HC mixture compositions for each loop. Based on the experimental results, the energy consumptions of the optimized dual-loop cycles using R-600a and HC mixtures were decreased by 14.2% and 18.6%, respectively, compared with that of a bypass two-circuit cycle using R-600a in the same RF platform. (C) 2012 Elsevier Ltd and IIR. All rights reserved.

키워드

HydrocarbonNon-azeotropic mixturePerformanceOptimizationHousehold refrigeratorSIMULATION
제목
Performance optimization of dual-loop cycles using R-600a and hydrocarbon mixtures designed for a domestic refrigerator-freezer
저자
Yoon, Won JaeSeo, KookjeongChung, Hyun JoonKim, Yongchan
DOI
10.1016/j.ijrefrig.2012.04.019
발행일
2012-09
유형
Article
저널명
International Journal of Refrigeration
35
6
페이지
1657 ~ 1667