상세 보기
Quality factor measurement of micro gyroscope structure according to vacuum level and desired Q-factor range package method
- Kim, Jong-Seok;
- Lee, Sang-Woo;
- Jung, Kyu-Dong;
- Kim, Woon-Bae;
- Choa, Sung-Hoon;
- ... Ju, Byeong-Kwon
WEB OF SCIENCE
8SCOPUS
9초록
A micro-machined gyro chip of gyroscope is normally packaged in specific vacuum level to get the specific quality factor(Q-factor). if the Q-factor is too high, frequency tuning and the approximate matching between driving and sensing comb structure become difficult, and if the Q-factor is too low, its sensitivity decreases. The optimum Q-factor of our gyro chip design is 4000 range. To get this range, we measured the drive mode Q-factor as vacuum level of our gyro chip and we found that the vacuum level of the desired Q-factor 4000 is in the range of 740 mTorr. Based on this data, we fabricate the wafer level package gyro chip of the desired Q-factor by controlled the basic pressure of package bonding chamber just prior to the bonding process. After wafer level package process, we measured Q-factor of whole samples. Among 804 samples, 502 packaged gyro chips are worked and the Q-factor of 67% samples is between 3500 and 4500 range. (c) 2008 Elsevier Ltd. All rights reserved.
키워드
- 제목
- Quality factor measurement of micro gyroscope structure according to vacuum level and desired Q-factor range package method
- 저자
- Kim, Jong-Seok; Lee, Sang-Woo; Jung, Kyu-Dong; Kim, Woon-Bae; Choa, Sung-Hoon; Ju, Byeong-Kwon
- 발행일
- 2008-06
- 유형
- Article
- 권
- 48
- 호
- 6
- 페이지
- 948 ~ 952