An Experimental Design to Compare the Compatibility of Absorbable and Nonabsorbable Suture Materials in the Lateral Canthus Area

  • Vu, Que Anh
  • Choi, Kwang-Eon
  • Nguyen, Cong Trung
  • Baek, Sehyun
Citations

WEB OF SCIENCE

0
Citations

SCOPUS

0

초록

Polyglactin 910 (Vicryl) and polypropylene (Prolene) are common suture materials used in ophthalmic surgical procedures. However, there are limited studies assessing tissue reactions to different sutures in eyelid areas. In this study, these suture materials were used subcutaneously in 10 lateral canthi of 5 pigs. Clinical reactive score (CRS) was assessed 14 days and 60 days after surgery. On histology, subcutaneous tissue reactions were assessed by the presence of different inflammatory cells, and the aggregate tissue irritation score was calculated. CRS and the histology score did not differ between these sutures. None of the suture materials used were superior for use in the lateral canthi of pig eyes. Therefore, we recommend both of these sutures for use in the subcutaneous tissue of the eyelid area in animal experiments or clinical practice.

키워드

Absorbable suturelateral canthusnon-absorbable suturepig modelsuture materialsTISSUE RESPONSESSKINGROSS
제목
An Experimental Design to Compare the Compatibility of Absorbable and Nonabsorbable Suture Materials in the Lateral Canthus Area
저자
Vu, Que AnhChoi, Kwang-EonNguyen, Cong TrungBaek, Sehyun
DOI
10.1097/SCS.0000000000009743
발행일
2024-01
유형
Article
저널명
The Journal of Craniofacial Surgery
35
1
페이지
e32 ~ e34