상세 보기
Evaluation based on performance and failure of PV system in 10 years field-aged 1 MW PV power plant
- Oh, Wonwook;
- Choi, Hoonjoo;
- Seo, Kun Won;
- Kim, Daesung;
- Kim, So-Yeon;
- ... Lee, Hae-Seok;
- 외 2명
WEB OF SCIENCE
12SCOPUS
12초록
PV (Photovoltaic) power systems have been rapidly installed and spreading worldwide in recent years. And there is a belief that the PV power plant will operate stably for more than 25 years. However, the PV modules have an unexpected failure. In this paper, we diagnosed a 10-year-old power plant using drone with infra-red (IR) camera, current-voltage (I-V) and electroluminescence (EL) measurement. The approximately 1 MW plant, consisting of two different PV modules, 200 W and 220 W, showed various failure modes. 59% PV modules failure caused an output loss, and an inverter with a serious loss is expected to degrade more than its annual degradation rate in PV strings above 40%. As a result, the power loss was quantitatively estimated to hot spot, bypass diode failure and degradation rate, and the capacity of the current PV system was evaluated at 88.3% and 93.2%.
키워드
- 제목
- Evaluation based on performance and failure of PV system in 10 years field-aged 1 MW PV power plant
- 저자
- Oh, Wonwook; Choi, Hoonjoo; Seo, Kun Won; Kim, Daesung; Kim, So-Yeon; Lee, Hae-Seok; Hwang, Heon; Kim, Donghwan
- 발행일
- 2020-11
- 유형
- Article
- 권
- 114