상세 보기
Diagnostic Assay of Glucose in Diabetes Patients' Urine
- Ly, Suw Young;
- Choi, Dal Woong;
- Kim, Dae Hong
Citations
WEB OF SCIENCE
2Citations
SCOPUS
2초록
Diagnosis of glucose (C6H12O6) was directly performed in non-treated urine. The cyclic voltammetry (CV) and square-wave stripping votammetric (SW) parameters were sought using platinum, mercury, and sodium immobilized on a graphite pencil probe. The platinum-coated graphite (PCG) probe is more sensitive than its modifications. The optimum analytical conditions were sought via SW and CV in 1-ml raw urine. Here analytical detection limit (S/N = 3) was attained to 0.6 mg L-1 glucose. Under 10.0 mg L-1 glucose constant, the standard deviation of 0.0016 (n = 15) was obtained. These results can be applied to the urine of diabetes patients and of healthy people.
키워드
Diagnosis; Diabetes; Patients' Urine; Glucose; In-Vivo Vesica; BIOSENSOR; BRAIN; ELECTRODES; TISSUE; IONS
- 제목
- Diagnostic Assay of Glucose in Diabetes Patients' Urine
- 저자
- Ly, Suw Young; Choi, Dal Woong; Kim, Dae Hong
- 발행일
- 2013-10
- 유형
- Article
- 저널명
- Sensor Letters
- 권
- 11
- 호
- 10
- 페이지
- 1996 ~ 1999