Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

밀폐형 돈사 작업장의 전체 환기율이 가스상 오염물질 노출 농도 변화에 미치는 영향Effect of General Ventilation Rate on Concentrations of Gaseous Pollutants Emitted from Enclosed Pig Building

Other Titles
Effect of General Ventilation Rate on Concentrations of Gaseous Pollutants Emitted from Enclosed Pig Building
Authors
김기연서성철최정학
Issue Date
2014
Publisher
한국산업보건학회
Keywords
Ammonia; Hydrogen sulfide; Odor concentration index; Pig building; Ventilation rate
Citation
한국산업보건학회지, v.24, no.1, pp.46 - 51
Indexed
KCI
Journal Title
한국산업보건학회지
Volume
24
Number
1
Start Page
46
End Page
51
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/100303
DOI
10.15269/JKSOEH.2014.24.1.046
ISSN
2384-132x
Abstract
Objectives: The principal aim of this study was to compare the concentrations of gaseous pollutants emitted in enclosed pig buildings between different rates of general ventilation and determine the variations in the patterns of gaseous pollutants as affected by ventilation rate. Materials and Methods: The experiment was performed in the growing/finishing room(20.0m×2.0m×3.0m) of a pig confinement building located on the experimental farm of Seoul National University. The conditions of the general ventilation rate for three treatments were 30%(4.12㎥ s-1), 50%(6.87㎥ s-1) and 70%(9.61㎥ s-1). The data presented in the study were collected overa total of 45 days, 15 days for each of the three treatments from March to May 2011. A total of six air samplings were taken at 1.5m above the floor of the pig building. The environmental agents measured in the pig building were ammonia, hydrogen sulfide and odor concentration index for gaseous pollutantswith temperature and hydrogen sulfide for thermal factors. Results: There were significant differences in the ammonia and odor concentration index in the pig building among the three general ventilation rate conditions (p<0.05), whereas hydrogen sulfide did not show a significant difference among three conditions of general ventilation rate(p>0.05). As the general ventilation rate applied to the pig building increases, it appears that all the indoor environmental agents measured in this study simultaneously decrease. Conclusions: The gaseous pollutants significantly affected by the general ventilation rate in pig building were ammonia and odor concentration index(p<0.05). However, it was found that hydrogen sulfide and thermal factors, temperature and relative humiditywere not influenced significantly by variation in the general ventilation rate.
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE