Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Effects of the high-power pain threshold ultrasound technique in the elderly with latent myofascial trigger points: A double-blind randomized study

Authors
Kim, YushinYang, Hong-RyeolLee, Jae-WooYoon, Bum-Chul
Issue Date
2014
Publisher
IOS PRESS
Keywords
Aged; high-power pain threshold; interventional ultrasound; myofascial pain syndromes; trigger points
Citation
JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, v.27, no.1, pp.17 - 23
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION
Volume
27
Number
1
Start Page
17
End Page
23
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/101208
DOI
10.3233/BMR-130414
ISSN
1053-8127
Abstract
BACKGROUND AND OBJECTIVE: The high-power pain threshold ultrasound (HPPTUS) technique has been introduced as a novel treatment method in patients with myofascial trigger points (MTrPs). The aim of the current study was to compare the therapeutic effects of HPPTUS with those of the conventional ultrasound technique in elderly patients with latent MTrPs on the upper trapezius muscles of at least 1 side. MATERIAL AND METHODS: Forty-one participants received 8 treatment sessions with conventional ultrasound (n = 19) or with the HPPTUS technique (n = 22) for 4 consecutive weeks. Outcome variables included visual analog scale (VAS) scores, pressure pain threshold (PPT), and range of motion (ROM). The data were analyzed using repeated analysis of variance (ANOVA) measurements. RESULTS: The VAS scores recorded 1, 2, 3, and 4 weeks after HPPTUS were significantly lower than the baseline scores in both groups. The ROM (after 3 and 4 weeks) and PPT (after 4 weeks) values also significantly increased from their baseline values in both groups. On comparing the techniques, there were no significant differences in the VAS (p = 0.296), PPT (p = 0.768), and ROM (p = 0.822) values, although both techniques showed therapeutic effects for 4 weeks (p < 0.001). CONCLUSION: The results indicate that the HPPTUS technique in same manner as treatment of active MTrPs is not superior to the conventional ultrasound technique in the treatment of the elderly patients with the latent MTrPs.