Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Method Validation of 16 Types of Structural Amino Acids using an Automated Amino Acid Analyzer

Full metadata record
DC Field Value Language
dc.contributor.authorShim, You-Shin-
dc.contributor.authorYoon, Won-Jin-
dc.contributor.authorHa, Jaeho-
dc.contributor.authorSeo, Dongwon-
dc.contributor.authorLee, Kwang-Won-
dc.contributor.authorLee, Woo-Young-
dc.contributor.authorKwon, Kwang-Il-
dc.contributor.authorKang, Tae-Seok-
dc.contributor.authorLee, Jin-Ha-
dc.contributor.authorKim, Hyun-Jeong-
dc.contributor.authorKwak, Hae-Jung-
dc.contributor.authorLee, Sam-Pin-
dc.contributor.authorKim, So-Jung-
dc.contributor.authorYun, Won-Kap-
dc.contributor.authorLee, Junsoo-
dc.contributor.authorHwang, Jin-Bong-
dc.date.accessioned2021-09-05T18:29:12Z-
dc.date.available2021-09-05T18:29:12Z-
dc.date.created2021-06-15-
dc.date.issued2013-12-
dc.identifier.issn1226-7708-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/101488-
dc.description.abstractAn analytical method for the simultaneous determination of 16 types of structural amino acids in infant formula using an automated amino acid analyzer was validated through tests of precision, accuracy and linearity. The automated analysis of the amino acids was performed on an ion-exchange packed column with a visible detector. The certificated reference material (CRM) 1546 from NIST was used as the test sample to determine the precision and accuracy of the analytical method. The regression analyses revealed good correlations [correlation coefficient (r(2))] that were greater than 0.99. The recovery values of the amino acids were ranged from 87.18 to 118.08%. The limits of detection and limits of quantification were less than 0.059 mg/100 g and less than 0.198 mg/100 g, respectively. The infra- and inter-day precisions were less than 14.62% in the CRM sample.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherKOREAN SOCIETY FOOD SCIENCE & TECHNOLOGY-KOSFOST-
dc.subjectCHROMATOGRAPHY-MASS-SPECTROMETRY-
dc.subjectPRECOLUMN DERIVATIZATION-
dc.subjectPERFORMANCE-
dc.subjectDERIVATIVES-
dc.subjectMS/MS-
dc.subjectFLUIDS-
dc.subjectSERUM-
dc.titleMethod Validation of 16 Types of Structural Amino Acids using an Automated Amino Acid Analyzer-
dc.typeArticle-
dc.contributor.affiliatedAuthorLee, Kwang-Won-
dc.identifier.doi10.1007/s10068-013-0252-0-
dc.identifier.scopusid2-s2.0-84890943537-
dc.identifier.wosid000329474200012-
dc.identifier.bibliographicCitationFOOD SCIENCE AND BIOTECHNOLOGY, v.22, no.6, pp.1567 - 1571-
dc.relation.isPartOfFOOD SCIENCE AND BIOTECHNOLOGY-
dc.citation.titleFOOD SCIENCE AND BIOTECHNOLOGY-
dc.citation.volume22-
dc.citation.number6-
dc.citation.startPage1567-
dc.citation.endPage1571-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.identifier.kciidART001839596-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaFood Science & Technology-
dc.relation.journalWebOfScienceCategoryFood Science & Technology-
dc.subject.keywordPlusCHROMATOGRAPHY-MASS-SPECTROMETRY-
dc.subject.keywordPlusPRECOLUMN DERIVATIZATION-
dc.subject.keywordPlusPERFORMANCE-
dc.subject.keywordPlusDERIVATIVES-
dc.subject.keywordPlusMS/MS-
dc.subject.keywordPlusFLUIDS-
dc.subject.keywordPlusSERUM-
dc.subject.keywordAuthoramino acids-
dc.subject.keywordAuthorautomated amino acid analyzer-
dc.subject.keywordAuthoranalytical method-
dc.subject.keywordAuthorvalidation-
dc.subject.keywordAuthorpost column reaction-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Biotechnology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Kwang Won photo

Lee, Kwang Won
Department of Biotechnology
Read more

Altmetrics

Total Views & Downloads

BROWSE