Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Diffusion Tensor Imaging of Extraocular Muscle Using Two-Dimensional Single-Shot Interleaved Multiple Inner Volume Imaging Diffusion-Weighted EPI at 3 Tesla

Authors
Seo, Hyung SukKim, Seong-EunRose, JohnHadley, J. RockParker, Dennis L.Jeong, Eun-Kee
Issue Date
11월-2013
Publisher
WILEY
Keywords
diffusion tensor imaging; orbit; muscle
Citation
JOURNAL OF MAGNETIC RESONANCE IMAGING, v.38, no.5, pp.1162 - 1168
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF MAGNETIC RESONANCE IMAGING
Volume
38
Number
5
Start Page
1162
End Page
1168
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/101733
DOI
10.1002/jmri.24095
ISSN
1053-1807
Abstract
PurposeTo evaluate the feasibility of diffusion tensor imaging (DTI) for the medial and lateral rectus extraocular muscle (EOM) evaluation, to investigate the normal DTI parameters of the medial and lateral rectus EOM, and to compare with other skeletal muscle. Materials and MethodsSeven multiple sclerosis patients and five normal subjects (M:F = 5:7, mean age = 31.6 9.2) without EOM disorder were included. The orbital DTIs using 2D-ss-IMVI-DWEPI were scanned with b = 500 s/mm(2) and 12 directions. The mean diffusivity (MD) and fractional anisotrophy (FA) of medial and lateral rectus EOMs in both orbits, and temporalis muscles were measured in regions of interest on two consecutive axial slices. Student t-test was performed to compare the mean apparent diffusion coefficient and FA values between medial and lateral rectus EOMs, and between EOMs and temporalis muscles. ResultsThe MDs in medial (0.58 +/- 0.18 x 10(-3)mm(2)/s) and lateral rectus EOMs (0.71 +/- 0.18 x 10(-3)mm(2)/s) were significantly lower than temporalis muscle (0.84 +/- 0.14 x 10(-3) mm(2)/s) (P < 0.001, respectively). The MD in medial rectus EOM was significantly lower than lateral rectus EOM (P = 0.001). The FAs in medial (0.40 +/- 0.05) and lateral rectus EOMs (0.40 +/- 0.05) were significantly higher than temporalis muscle (0.25 +/- 0.05) (P < 0.001, respectively). There was no significant difference between the FAs in medial and lateral rectus EOMs (P > 0.05). ConclusionThe MDs of EOMs were lower and the FAs were higher than those of skeletal muscle. These are well correlated to the unique characteristics of EOMs. J. Magn. Reson. Imaging 2013;38:1162-1168. (c) 2013 Wiley Periodicals, Inc.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE