Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

White light scanner-based repeatability of 3-dimensional digitizing of silicon rubber abutment teeth impressions

Authors
Jeon, Jin-HunLee, Kyung-TakKim, Hae-YoungKim, Ji-HwanKim, Woong-Chul
Issue Date
11월-2013
Publisher
KOREAN ACAD PROSTHODONTICS
Keywords
Dental white light scanner; Repeatability; Digital impression; 3D-surface model
Citation
JOURNAL OF ADVANCED PROSTHODONTICS, v.5, no.4, pp.452 - 456
Indexed
SCIE
SCOPUS
KCI
Journal Title
JOURNAL OF ADVANCED PROSTHODONTICS
Volume
5
Number
4
Start Page
452
End Page
456
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/101805
DOI
10.4047/jap.2013.5.4.452
ISSN
2005-7806
Abstract
PURPOSE. The aim of this study was to evaluate the repeatability of the digitizing of silicon rubber impressions of abutment teeth by using a white light scanner and compare differences in repeatability between different abutment teeth types. MATERIALS AND METHODS. Silicon rubber impressions of a canine, premolar, and molar tooth were each digitized 8 times using a white light scanner, and 3D surface models were created using the point clouds. The size of any discrepancy between each model and the corresponding reference tooth were measured, and the distribution of these values was analyzed by an inspection software (PowerInspect 2012, Delcamplc., Birmingham, UK). Absolute values of discrepancies were analyzed by the Kruskal-Wallis test and multiple comparisons (alpha=.05). RESULTS. The discrepancy between the impressions for the canine, premolar, and molar teeth were 6.3 mu m (95% confidence interval [CI], 5.4-7.2), 6.4 mu m (95% CI, 5.3-7.6), and 8.9 mu m (95% CI, 8.2-9.5), respectively. The discrepancy of the molar tooth impression was significantly higher than that of other tooth types. The largest variation (as mean [SD]) in discrepancies was seen in the premolar tooth impression scans: 26.7 mu m (95% CI, 19.7-33.8); followed by canine and molar teeth impressions, 16.3 mu m (95% CI, 15.3-17.3), and 14.0 mu m (95% CI, 12.3-15.7), respectively. CONCLUSION. The repeatability of the digitizing abutment teeth's silicon rubber impressions by using a white light scanner was improved compared to that with a laser scanner, showing only a low mean discrepancy between 6.3 pm and 8.9 pm, which was in an clinically acceptable range. Premolar impression with a long and narrow shape showed a significantly larger discrepancy than canine and molar impressions. Further work is needed to increase the digitizing performance of the white light scanner for deep and slender impressions.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > Division of Health Policy and Management > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Ji Hwan photo

Kim, Ji Hwan
보건과학대학 (보건정책관리학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE