Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Electro-migration of impurities in TlBr

Authors
Kim, Ki HyunKim, EunlimKim, H.Tappero, R.Bolotnikov, A. E.Camarda, G. S.Hossain, A.Cirignano, L.James, R. B.
Issue Date
7-10월-2013
Publisher
AMER INST PHYSICS
Citation
JOURNAL OF APPLIED PHYSICS, v.114, no.13
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF APPLIED PHYSICS
Volume
114
Number
13
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/101891
DOI
10.1063/1.4823781
ISSN
0021-8979
Abstract
We observed the electro-migration of Cu, Ag, and Au impurities that exist in positive-ion states in TlBr detectors under electric field strengths typically used for device operation. The migration occurred predominantly through bulk-and specific-channels, which are presumed to be a network of grain and sub-grain boundaries. The electro-migration velocity of Cu, Ag, and Au in TlBr is about 4-8 x 10(-8) cm/s at room temperature under an electric field of 500-800 V/mm. The instability and polarization effects of TlBr detectors might well be correlated with the electro-migration of residual impurities in TlBr, which alters the internal electric field over time. The effect may also have been due to migration of the electrode material itself, which would allow for the possibility of a better choice for contact material and for depositing an effective diffusion barrier. From our findings, we suggest that applying our electro-migration technique for purifying material is a promising new way to remove electrically active metallic impurities in TlBr crystals, as well as other materials. (C) 2013 AIP Publishing LLC.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > School of Health and Environmental Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE