dc.description.abstractDiagnosis of glucose (C6H12O6) was directly performed in non-treated urine. The cyclic voltammetry (CV) and square-wave stripping votammetric (SW) parameters were sought using platinum, mercury, and sodium immobilized on a graphite pencil probe. The platinum-coated graphite (PCG) probe is more sensitive than its modifications. The optimum analytical conditions were sought via SW and CV in 1-ml raw urine. Here analytical detection limit (S/N = 3) was attained to 0.6 mg L-1 glucose. Under 10.0 mg L-1 glucose constant, the standard deviation of 0.0016 (n = 15) was obtained. These results can be applied to the urine of diabetes patients and of healthy people.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherAMER SCIENTIFIC PUBLISHERS-
dc.subjectBIOSENSOR-
dc.subjectBRAIN-
dc.subjectELECTRODES-
dc.subjectTISSUE-
dc.subjectIONS-
dc.titleDiagnostic Assay of Glucose in Diabetes Patients' Urine-
dc.typeArticle-
dc.contributor.affiliatedAuthorChoi, Dal Woong-
dc.identifier.doi10.1166/sl.2013.3016-
dc.identifier.scopusid2-s2.0-84896770976-
dc.identifier.wosid000332845400023-
dc.identifier.bibliographicCitationSENSOR LETTERS, v.11, no.10, pp.1996 - 1999-
dc.relation.isPartOfSENSOR LETTERS-
dc.citation.titleSENSOR LETTERS-
dc.citation.volume11-
dc.citation.number10-
dc.citation.startPage1996-
dc.citation.endPage1999-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalResearchAreaElectrochemistry-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalWebOfScienceCategoryElectrochemistry-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryPhysics, Applied-
dc.subject.keywordPlusBIOSENSOR-
dc.subject.keywordPlusBRAIN-
dc.subject.keywordPlusELECTRODES-
dc.subject.keywordPlusTISSUE-
dc.subject.keywordPlusIONS-
dc.subject.keywordAuthorDiagnosis-
dc.subject.keywordAuthorDiabetes-
dc.subject.keywordAuthorPatients&apos-
dc.subject.keywordAuthorUrine-
dc.subject.keywordAuthorGlucose-
dc.subject.keywordAuthorIn-Vivo Vesica-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > School of Health and Environmental Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE