Diagnostic Assay of Glucose in Diabetes Patients' Urine
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ly, Suw Young | - |
dc.contributor.author | Choi, Dal Woong | - |
dc.contributor.author | Kim, Dae Hong | - |
dc.date.accessioned | 2021-09-05T20:35:08Z | - |
dc.date.available | 2021-09-05T20:35:08Z | - |
dc.date.created | 2021-06-15 | - |
dc.date.issued | 2013-10 | - |
dc.identifier.issn | 1546-198X | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/101979 | - |
dc.description.abstract | Diagnosis of glucose (C6H12O6) was directly performed in non-treated urine. The cyclic voltammetry (CV) and square-wave stripping votammetric (SW) parameters were sought using platinum, mercury, and sodium immobilized on a graphite pencil probe. The platinum-coated graphite (PCG) probe is more sensitive than its modifications. The optimum analytical conditions were sought via SW and CV in 1-ml raw urine. Here analytical detection limit (S/N = 3) was attained to 0.6 mg L-1 glucose. Under 10.0 mg L-1 glucose constant, the standard deviation of 0.0016 (n = 15) was obtained. These results can be applied to the urine of diabetes patients and of healthy people. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | AMER SCIENTIFIC PUBLISHERS | - |
dc.subject | BIOSENSOR | - |
dc.subject | BRAIN | - |
dc.subject | ELECTRODES | - |
dc.subject | TISSUE | - |
dc.subject | IONS | - |
dc.title | Diagnostic Assay of Glucose in Diabetes Patients' Urine | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Choi, Dal Woong | - |
dc.identifier.doi | 10.1166/sl.2013.3016 | - |
dc.identifier.scopusid | 2-s2.0-84896770976 | - |
dc.identifier.wosid | 000332845400023 | - |
dc.identifier.bibliographicCitation | SENSOR LETTERS, v.11, no.10, pp.1996 - 1999 | - |
dc.relation.isPartOf | SENSOR LETTERS | - |
dc.citation.title | SENSOR LETTERS | - |
dc.citation.volume | 11 | - |
dc.citation.number | 10 | - |
dc.citation.startPage | 1996 | - |
dc.citation.endPage | 1999 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalResearchArea | Electrochemistry | - |
dc.relation.journalResearchArea | Instruments & Instrumentation | - |
dc.relation.journalResearchArea | Physics | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
dc.relation.journalWebOfScienceCategory | Electrochemistry | - |
dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
dc.relation.journalWebOfScienceCategory | Physics, Applied | - |
dc.subject.keywordPlus | BIOSENSOR | - |
dc.subject.keywordPlus | BRAIN | - |
dc.subject.keywordPlus | ELECTRODES | - |
dc.subject.keywordPlus | TISSUE | - |
dc.subject.keywordPlus | IONS | - |
dc.subject.keywordAuthor | Diagnosis | - |
dc.subject.keywordAuthor | Diabetes | - |
dc.subject.keywordAuthor | Patients&apos | - |
dc.subject.keywordAuthor | Urine | - |
dc.subject.keywordAuthor | Glucose | - |
dc.subject.keywordAuthor | In-Vivo Vesica | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.