Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Percutaneous Placement of Self-Expandable Metallic Stents in Patients with Obstructive Jaundice Secondary to Metastatic Gastric Cancer after Gastrectomy

Authors
Hong, Hyun PyoSeo, Tae-SeokCha, In-HoYu, Jung RimMok, Young JaeOh, Joo HyeongKwon, Se HwanKim, Sam SooKim, Seung Kwon
Issue Date
9월-2013
Publisher
KOREAN RADIOLOGICAL SOC
Keywords
Biliary tract, malignant obstruction; Biliary tract, interventional procedures; Prosthesis, stent; Gastric carcinoma
Citation
KOREAN JOURNAL OF RADIOLOGY, v.14, no.5, pp.789 - 796
Indexed
SCIE
SCOPUS
KCI
Journal Title
KOREAN JOURNAL OF RADIOLOGY
Volume
14
Number
5
Start Page
789
End Page
796
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/102321
DOI
10.3348/kjr.2013.14.5.789
ISSN
1229-6929
Abstract
Objective: To evaluate the outcomes of patients undergoing percutaneous placements of a biliary stent for obstructive jaundice secondary to metastatic gastric cancer after gastrectomy. Materials and Methods: Fifty patients (mean age, 62.4 years; range, 27-86 years) who underwent percutaneous placements of a biliary stent for obstructive jaundice secondary to metastatic gastric cancer after gastrectomy were included. The technical success rate, clinical success rate, complication rate, stent patency, patient survival and factors associated with stent patency were being evaluated. Results: The median interval between the gastrectomy and stent placement was 23.1 months (range, 3.9-94.6 months). The 50 patients received a total of 65 stents without any major procedure-related complications. Technical success was achieved in all patients. The mean total serum bilirubin Level, which had been 7.19 mg/dL +/- 6.8 before stent insertion, decreased to 4.58 mg/dL +/- 5.4 during the first week of follow-up (p < 0.001). Clinical success was achieved in 42 patients (84%). Percutaneous transhepatic biliary drainage catheters were removed from 45 patients (90%). Infectious complications were noted in two patients (4%), and stent malfunction occurred in seven patients (14%). The median stent patency was 233 +/- 99 days, and the median patient survival was 179 +/- 83 days. Total serum bilirubin level after stenting was an independent factor for stent patency (p = 0.009). Conclusion: Percutaneous transhepatic placement of a biliary stent for obstructive jaundice secondary to metastatic gastric cancer after gastrectomy is a technically feasible and clinically effective palliative procedure.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Seo, Tae Seok photo

Seo, Tae Seok
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE