Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

An evaluation of marginal fit of three-unit fixed dental prostheses fabricated by direct metal laser sintering system

Authors
Kim, Ki-BaekKim, Woong-ChulKim, Hae-YoungKim, Ji-Hwan
Issue Date
7월-2013
Publisher
ELSEVIER SCI LTD
Keywords
Absolute marginal discrepancy; Marginal gap; Internal gap; Direct metal laser sintering
Citation
DENTAL MATERIALS, v.29, no.7, pp.E91 - E96
Indexed
SCIE
SCOPUS
Journal Title
DENTAL MATERIALS
Volume
29
Number
7
Start Page
E91
End Page
E96
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/102837
DOI
10.1016/j.dental.2013.04.007
ISSN
0109-5641
Abstract
Objectives. This in vitro study aimed to evaluate and compare marginal fit of three-unit fixed dental prostheses (FDPs) fabricated using a newly developed direct metal laser sintering (DMLS) system with that of three-unit FDPs by a conventional lost wax technique (LW) method. Methods. Ten cobalt-chromium alloy three-unit FDPs using DMLS system and another ten nickel-chromium alloy FDPs using LW method were fabricated. Marginal fit was examined using a light-body silicone. After setting, the silicon film was cut into four parts and the thickness of silicon layer was measured at 160x magnification using a digital microscope to measure absolute marginal discrepancy (AMD), marginal gap (MG) and internal gap (IG). A repeated measure ANOVA for statistical analysis was performed using the SPSS statistical package version 12.0 (alpha = 0.05). Results. The mean values of AMD, MG, and IG were significantly larger in the DMLS group than in the LW group (p < 0.001). Means of AMD, MG and IG in the first molars were 83.3, 80.0, and 82.0 mu m in the LW group; and 128.0, 112.0, and 159.5 mu m in the DMLS group, respectively. No significant difference between measurements for premolars and molars was found (p > 0.05). Significance. The marginal fit of the DMLS system appeared significantly inferior compared to that of the conventional LW method and slightly larger than the acceptable range. For clinical application further improvement of DMLS system may be required. (C) 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > Division of Health Policy and Management > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Ji Hwan photo

Kim, Ji Hwan
보건과학대학 (보건정책관리학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE