Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Upper torso and pelvis linear velocity during the downswing of elite golfers

Authors
Beak, Seung-HuiChoi, AhnryulChoi, Seung-WookOh, Seung EelMun, Joung HwanYang, HeegooSim, TaeyongSong, Hae-Ryong
Issue Date
11-2월-2013
Publisher
BIOMED CENTRAL LTD
Keywords
Golf; Linear velocity; Coupling; Cross-correlation; Downswing
Citation
BIOMEDICAL ENGINEERING ONLINE, v.12
Indexed
SCIE
SCOPUS
Journal Title
BIOMEDICAL ENGINEERING ONLINE
Volume
12
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/103969
DOI
10.1186/1475-925X-12-13
ISSN
1475-925X
Abstract
Background: During a golf swing, analysis of the movement in upper torso and pelvis is a key step to determine a motion control strategy for accurate and consistent shots. However, a majority of previous studies that have evaluated this movement limited their analysis only to the rotational movement of segments, and translational motions were not examined. Therefore, in this study, correlations between translational motions in the 3 axes, which occur between the upper torso and pelvis, were also examined. Methods: The experiments were carried out with 14 male pro-golfers (age: 29 +/- 8 years, career: 8.2 +/- 4.8years) who registered in the Korea Professional Golf Association (KPGA). Six infrared cameras (VICON; Oxford Metrics, Oxford, UK) and SB-Clinc software (SWINGBANK Ltd, Korea) were used to collect optical marker trajectories. The center of mass (CoM) of each segment was calculated based on kinematic principal. In addition, peak value of CoM velocity and the time that each peak occurred in each segment during downswing was calculated. Also, using cross-correlation analysis, the degree of coupling and time lags of peak values occurred between and within segments (pelvis and upper torso) were investigated. Results: As a result, a high coupling strength between upper torso and pelvis with an average correlation coefficient = 0.86 was observed, and the coupling between segments was higher than that within segments (correlation coefficient = 0.81 and 0.77, respectively). Conclusions: Such a high coupling at the upper torso and pelvis can be used to reduce the degree of motion control in the central nervous system and maintain consistent patterns in the movement. The result of this study provides important information for the development of optimal golf swing movement control strategies in the future.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Biomedical Sciences > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE