Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

초기 확산강조 MR 영상에서 음성을 보인 급성기 뇌경색 환자의 임상 양상Clinical Features of Patients with False Negative Diffusion-weighted MR Findings in Acute Ischemic Stroke

Other Titles
Clinical Features of Patients with False Negative Diffusion-weighted MR Findings in Acute Ischemic Stroke
Authors
남궁인한갑수조한진문성우최성혁이병찬
Issue Date
2013
Publisher
대한응급의학회
Keywords
Cerebral infarction; Diffusion magnetic resonance imaging MRI; Brain stem
Citation
대한응급의학회지, v.24, no.4, pp.396 - 402
Indexed
KCI
Journal Title
대한응급의학회지
Volume
24
Number
4
Start Page
396
End Page
402
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/105264
ISSN
1226-4334
Abstract
Purpose: Diffusion-weighted magnetic resonance (MR)image (DWI) has advantages for the assessment of acute stroke. However, false negative DWI findings in acute ischemic stroke have been reported. Our purpose was to estimate the rate of initial false negative DWI studies in acute ischemic stroke patients and to identify characteristics of false negative DWI stroke patients. Methods: In this retrospective study from January 2010 to June 2011, acute ischemic stroke patients (within 6 hours after stroke onset) were enrolled. A total of 56 patients were included in this study. Cases with negative initial DWI findings,with an ischemic lesion visible on follow-up MR studies,were analyzed for times between the onset of symptoms and initial DWI, National Institute of Health Stroke Scale (NIHSS), and the location of the ischemic stroke lesion. Results: We found seven cases (12.5%) of false negative initial DWI studies. The initial false negative DWI group had a significantly shorter time from the onset of symptoms to the initial DWI compared to the initial positive DWI group (p=0.011). The false negative group had a lower NIHSS without significance (p=0.091). Conclusion: A false-negative DWI study is not uncommon in the assessment of acute ischemic stroke. Thus, patients suspected of having a stroke should not be ruled out on the basis of a negative DWI, especially a suspected low NIHSS, for an early onset of symptoms.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choi, Sung Hyuk photo

Choi, Sung Hyuk
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE