Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Customized Cranioplasty Implants Using Three-Dimensional Printers and Polymethyl-Methacrylate Casting

Authors
Kim, Bum-JoonHong, Ki-SunPark, Kyung-JaePark, Dong-HyukChung, Yong-GuKang, Shin-Hyuk
Issue Date
Dec-2012
Publisher
KOREAN NEUROSURGICAL SOC
Keywords
Decompressive craniectomy; Reconstructive surgical procedure; Computer-aided design; Polymethyl-methacrylate
Citation
JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, v.52, no.6, pp.541 - 546
Indexed
SCIE
SCOPUS
KCI
Journal Title
JOURNAL OF KOREAN NEUROSURGICAL SOCIETY
Volume
52
Number
6
Start Page
541
End Page
546
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/106755
DOI
10.3340/jkns.2012.52.6.541
ISSN
2005-3711
Abstract
Objective : The prefabrication of customized cranioplastic implants has been introduced to overcome the difficulties of intra-operative implant molding. The authors present a new technique, which consists of the prefabrication of implant molds using three-dimensional (3D) printers and polymethyl-methacrylate (PMMA) casting. Methods : A total of 16 patients with large skull defects (>100 cm(2)) underwent cranioplasty between November 2009 and April 2011. For unilateral cranial defects, 3D images of the skull were obtained from preoperative axial 1-mm spiral computed tomography (CT) scans. The image of the implant was generated by a digital subtraction mirror-imaging process using the normal side of the cranium as a model. For bilateral cranial defects, precraniectomy routine spiral CT scan data were merged with postcraniectomy 3D CT images following a smoothing process. Prefabrication of the mold was performed by the 3D printer. Intraoperatively, the PMMA implant was created with the prefabricated mold, and fit into the cranial defect. Results : The median operation time was 184.36 +/- 26.07 minutes. Postoperative CT scans showed excellent restoration of the symmetrical contours and curvature of the cranium in all cases. The median follow-up period was 23 months (range, 14-28 months). Postoperative infection was developed in one case (6.2%) who had an open wound defect previously. Conclusion : Customized cranioplasty PMMA implants using 3D printer may be a useful technique for the reconstruction of various cranial defects.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Dong Hyuk photo

Park, Dong Hyuk
College of Medicine (Department of Medical Science)
Read more

Altmetrics

Total Views & Downloads

BROWSE