A biomechanical evaluation of proximal femoral nail antirotation with respect to helical blade position in femoral head: A cadaveric study
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Hwang, Jin-Ho | - |
dc.contributor.author | Garg, Anant Kumar | - |
dc.contributor.author | Oh, Jong-Keon | - |
dc.contributor.author | Oh, Chang-Wug | - |
dc.contributor.author | Lee, Sung-Jae | - |
dc.contributor.author | Myung-Rae, Cho | - |
dc.contributor.author | Kim, Min-Keun | - |
dc.contributor.author | Kim, Hyun | - |
dc.date.accessioned | 2021-09-06T13:37:28Z | - |
dc.date.available | 2021-09-06T13:37:28Z | - |
dc.date.created | 2021-06-15 | - |
dc.date.issued | 2012-11 | - |
dc.identifier.issn | 0019-5413 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/106995 | - |
dc.description.abstract | Objective: Despite new developments in the management of osteoporotic fractures, complications like screw cutout are still found in the fixation of proximal femur fractures even with biomechanically proven better implants like proximal femoral nail antirotation (PFNA). The purpose of this cadaveric study was to investigate the biomechanical stability of this device in relation to two common positions (center-center and inferior-center) of the helical blade in the femoral head in unstable trochanteric fractures. Materials and Methods: Eight pairs of human cadaveric femurs were used; in one group [center-center (C-C) group], the helical blade of PFNA was fixed randomly in central position both in anteroposterior and lateral view, whereas in the other group it was fixed in inferior one-third position in anteroposterior and in central position in lateral view [inferior-center (I-C) group]. Unstable intertrochanteric fracture was created and each specimen was loaded cyclically till load to failure Results: Angular and rotational displacements were significantly higher within the C-C group compared to the I-C group in both unloaded and loaded condition. Loading to failure was higher in the I-C group compared to the C-C group. No statistical significance was found for this parameter. Correlations between tip apex distance, cyclic loading which lead to femoral head displacement, and ultimate load to failure showed a significant positive relationship. Conclusion: The I-C group was superior to the C-C group and provided better biomechanical stability for angular and rotational displacement. This study would be a stimulus for further experimental studies with larger number specimens and complex loading protocols at multicentres. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | SPRINGER HEIDELBERG | - |
dc.subject | DYNAMIC HIP SCREW | - |
dc.subject | INTERTROCHANTERIC FRACTURES | - |
dc.subject | PERITROCHANTERIC FRACTURES | - |
dc.subject | FIXATION TECHNIQUES | - |
dc.subject | INTERNAL-FIXATION | - |
dc.subject | SIDE PLATE | - |
dc.subject | COMPLICATIONS | - |
dc.subject | PLACEMENT | - |
dc.subject | FAILURE | - |
dc.subject | MODEL | - |
dc.title | A biomechanical evaluation of proximal femoral nail antirotation with respect to helical blade position in femoral head: A cadaveric study | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Oh, Jong-Keon | - |
dc.identifier.doi | 10.4103/0019-5413.104186 | - |
dc.identifier.scopusid | 2-s2.0-84871632579 | - |
dc.identifier.wosid | 000313295100004 | - |
dc.identifier.bibliographicCitation | INDIAN JOURNAL OF ORTHOPAEDICS, v.46, no.6, pp.627 - 632 | - |
dc.relation.isPartOf | INDIAN JOURNAL OF ORTHOPAEDICS | - |
dc.citation.title | INDIAN JOURNAL OF ORTHOPAEDICS | - |
dc.citation.volume | 46 | - |
dc.citation.number | 6 | - |
dc.citation.startPage | 627 | - |
dc.citation.endPage | 632 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Orthopedics | - |
dc.relation.journalWebOfScienceCategory | Orthopedics | - |
dc.subject.keywordPlus | DYNAMIC HIP SCREW | - |
dc.subject.keywordPlus | INTERTROCHANTERIC FRACTURES | - |
dc.subject.keywordPlus | PERITROCHANTERIC FRACTURES | - |
dc.subject.keywordPlus | FIXATION TECHNIQUES | - |
dc.subject.keywordPlus | INTERNAL-FIXATION | - |
dc.subject.keywordPlus | SIDE PLATE | - |
dc.subject.keywordPlus | COMPLICATIONS | - |
dc.subject.keywordPlus | PLACEMENT | - |
dc.subject.keywordPlus | FAILURE | - |
dc.subject.keywordPlus | MODEL | - |
dc.subject.keywordAuthor | Biomechanical study | - |
dc.subject.keywordAuthor | cadaveric study | - |
dc.subject.keywordAuthor | unstable trochanteric fracture | - |
dc.subject.keywordAuthor | helical blade position | - |
dc.subject.keywordAuthor | PFNA | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.