Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

A biomechanical evaluation of proximal femoral nail antirotation with respect to helical blade position in femoral head: A cadaveric study

Authors
Hwang, Jin-HoGarg, Anant KumarOh, Jong-KeonOh, Chang-WugLee, Sung-JaeMyung-Rae, ChoKim, Min-KeunKim, Hyun
Issue Date
11월-2012
Publisher
SPRINGER HEIDELBERG
Keywords
Biomechanical study; cadaveric study; unstable trochanteric fracture; helical blade position; PFNA
Citation
INDIAN JOURNAL OF ORTHOPAEDICS, v.46, no.6, pp.627 - 632
Indexed
SCIE
SCOPUS
Journal Title
INDIAN JOURNAL OF ORTHOPAEDICS
Volume
46
Number
6
Start Page
627
End Page
632
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/106995
DOI
10.4103/0019-5413.104186
ISSN
0019-5413
Abstract
Objective: Despite new developments in the management of osteoporotic fractures, complications like screw cutout are still found in the fixation of proximal femur fractures even with biomechanically proven better implants like proximal femoral nail antirotation (PFNA). The purpose of this cadaveric study was to investigate the biomechanical stability of this device in relation to two common positions (center-center and inferior-center) of the helical blade in the femoral head in unstable trochanteric fractures. Materials and Methods: Eight pairs of human cadaveric femurs were used; in one group [center-center (C-C) group], the helical blade of PFNA was fixed randomly in central position both in anteroposterior and lateral view, whereas in the other group it was fixed in inferior one-third position in anteroposterior and in central position in lateral view [inferior-center (I-C) group]. Unstable intertrochanteric fracture was created and each specimen was loaded cyclically till load to failure Results: Angular and rotational displacements were significantly higher within the C-C group compared to the I-C group in both unloaded and loaded condition. Loading to failure was higher in the I-C group compared to the C-C group. No statistical significance was found for this parameter. Correlations between tip apex distance, cyclic loading which lead to femoral head displacement, and ultimate load to failure showed a significant positive relationship. Conclusion: The I-C group was superior to the C-C group and provided better biomechanical stability for angular and rotational displacement. This study would be a stimulus for further experimental studies with larger number specimens and complex loading protocols at multicentres.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Oh, Jong Keon photo

Oh, Jong Keon
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE